TY - JOUR
T1 - A novel SIME configuration scheme correlating generator tripping for transient stability assessment
AU - Oh, Seung Chan
AU - Lee, Hwan Ik
AU - Lee, Yun Hwan
AU - Lee, Byong Jun
N1 - Funding Information:
This research was supported by Korea Electric Power Corporation (Grant number: R17XA05-4) and “Human Resource program in Energy Technology” of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea(No. 20174030201820).
Publisher Copyright:
© The Korean Institute of Electrical Engineers.
PY - 2018/9
Y1 - 2018/9
N2 - When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.
AB - When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.
KW - Generator tripping
KW - Power system stability
KW - SIME method
KW - Transient stability assessment
KW - Transient stability margin
UR - http://www.scopus.com/inward/record.url?scp=85052147172&partnerID=8YFLogxK
U2 - 10.5370/JEET.2018.13.5.1798
DO - 10.5370/JEET.2018.13.5.1798
M3 - Article
AN - SCOPUS:85052147172
SN - 1975-0102
VL - 13
SP - 1798
EP - 1806
JO - Journal of Electrical Engineering and Technology
JF - Journal of Electrical Engineering and Technology
IS - 5
ER -