Abstract
We measured hemodynamic responses of seizure in the mouse brain using frequencydomain near infrared spectroscopy (NIRS) and electroencephalogram (EEG). We adapted microfabricated optical holder for consistent contact of the optical fiber to the mouse brain. Our results show that the cerebral oxygenation and hemodynamics of mice can be stably monitored with EEG in the mouse brain.
Original language | English |
---|---|
Pages | BMD22 |
DOIs | |
Publication status | Published - 2008 |
Externally published | Yes |
Event | Biomedical Optics, BIOMED 2008 - St. Petersburg, FL, United States Duration: 2008 Mar 16 → 2008 Mar 19 |
Other
Other | Biomedical Optics, BIOMED 2008 |
---|---|
Country/Territory | United States |
City | St. Petersburg, FL |
Period | 08/3/16 → 08/3/19 |
ASJC Scopus subject areas
- Biomedical Engineering
- Biomaterials
- Electronic, Optical and Magnetic Materials
- Atomic and Molecular Physics, and Optics