Accuracy of 3D white light scanning of abutment teeth impressions: Evaluation of trueness and precision

Jin Hun Jeon, Hae Young Kim, Ji Hwan Kim, Woong Chul Kim

Research output: Contribution to journalArticlepeer-review

22 Citations (Scopus)

Abstract

Purpose. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. Materials and methods. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by 10°-20° and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (α=.05). Results. Precision discrepancies for the canine, premolar, and molar were 3.7 μm, 3.2 μm, and 7.3 μm, respectively, indicating the poorest precision for the molar (P < .001). Trueness discrepancies for teeth types were 6.2 μm, 11.2 μm, and 21.8 μm, respectively, indicating the poorest trueness for the molar (P=.007). Conclusion. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

Original languageEnglish
Pages (from-to)468-473
Number of pages6
JournalJournal of Advanced Prosthodontics
Volume6
Issue number6
DOIs
Publication statusPublished - 2014

Bibliographical note

Publisher Copyright:
© 2014 The Korean Academy of Prosthodontics.

Keywords

  • 3D shape data
  • Accuracy
  • Impression scanning
  • Point cloud
  • Precision and trueness
  • White light scanner

ASJC Scopus subject areas

  • Oral Surgery
  • Dentistry (miscellaneous)

Fingerprint

Dive into the research topics of 'Accuracy of 3D white light scanning of abutment teeth impressions: Evaluation of trueness and precision'. Together they form a unique fingerprint.

Cite this