N2 - Purpose: The all-inside arthroscopic modified Broström operation has been developed for lateral ankle instability. We compared the biomechanical parameters of the all-inside arthroscopic procedure to the open modified Broström operation. Methods: Eleven matched pairs of human cadaver specimens [average age 71.5 (range 58–98) years] were subject to the arthroscopic modified Broström operation using a suture anchor and the open modified Broström operation. The ligaments were loaded cyclically 20 times and then tested to failure. Torque to failure, degrees to failure, and stiffness were measured. A matched-pair analysis was performed. Results: There was no significant difference in torque to failure between the open and arthroscopic modified Broström operation (19.9 ± 8.9 vs. 23.3 ± 12.1 Nm, n.s). The degrees to failure did not differ significantly between the open and arthroscopic modified Broström operations (46.8 ± 9.9° vs. 46.7 ± 7.6°, n.s). The working construct stiffness (or stiffness to failure) was no significant difference in the two groups (0.438 ± 0.21 vs. 0.487 ± 0.268 Nm/deg for the open and arthroscopic modified Broström operations, respectively, n.s). Conclusion: The all-inside arthroscopic modified Broström operation and the open modified Broström operation resulted in no significantly different torque to failure, degrees to failure, and working construct stiffness with no significant differences (n.s, n.s, and n.s, respectively). Our results indicate that the arthroscopic modified Broström operation is a reasonable alternative procedure for chronic ankle instability.
AB - Purpose: The all-inside arthroscopic modified Broström operation has been developed for lateral ankle instability. We compared the biomechanical parameters of the all-inside arthroscopic procedure to the open modified Broström operation. Methods: Eleven matched pairs of human cadaver specimens [average age 71.5 (range 58–98) years] were subject to the arthroscopic modified Broström operation using a suture anchor and the open modified Broström operation. The ligaments were loaded cyclically 20 times and then tested to failure. Torque to failure, degrees to failure, and stiffness were measured. A matched-pair analysis was performed. Results: There was no significant difference in torque to failure between the open and arthroscopic modified Broström operation (19.9 ± 8.9 vs. 23.3 ± 12.1 Nm, n.s). The degrees to failure did not differ significantly between the open and arthroscopic modified Broström operations (46.8 ± 9.9° vs. 46.7 ± 7.6°, n.s). The working construct stiffness (or stiffness to failure) was no significant difference in the two groups (0.438 ± 0.21 vs. 0.487 ± 0.268 Nm/deg for the open and arthroscopic modified Broström operations, respectively, n.s). Conclusion: The all-inside arthroscopic modified Broström operation and the open modified Broström operation resulted in no significantly different torque to failure, degrees to failure, and working construct stiffness with no significant differences (n.s, n.s, and n.s, respectively). Our results indicate that the arthroscopic modified Broström operation is a reasonable alternative procedure for chronic ankle instability.
KW - All-inside
KW - Arthroscopic modified Broström technique
KW - Biomechanical
KW - Cadaver
UR - http://www.scopus.com/inward/record.url?scp=84940225302&partnerID=8YFLogxK
U2 - 10.1007/s00167-014-3159-2
DO - 10.1007/s00167-014-3159-2
M3 - Article
C2 - 24996867
AN - SCOPUS:84940225302
SN - 0942-2056
VL - 24
SP - 1096
EP - 1100
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
IS - 4
ER -