Comparison of osmolarity of various artificial tears products commercially available in South Korea

In Ho Woo, Jun Gi Hong, Jung Ah Huh, Youngsub Eom, Hyo Myung Kim, Jong Suk Song

    Research output: Contribution to journalArticlepeer-review

    2 Citations (Scopus)

    Abstract

    Purpose: To compare the osmolarity of various artificial tear products commercially available in the Republic of Korea. Methods: The osmolarity of the artificial tears was analyzed using TearLab® and Multi-Osmette™. We divided the artificial tear products into five groups, including hypo-osmolar 0.18% sodium hyaluronate (HA), iso-osmolar 0.1%, 0.15%, 0.3% HA, and 0.5% carboxymethylcellulose sodium (CMC), and measured three products per group. Results: Among the 12 products of iso-osmolar artificial tears, there were seven products (58.3%) < 300 mOsm/L, and among the three products of hypo-osmolar artificial tears, there were two products (66.6%) < 150 mOsm/L. A significant difference (p < 0.05) was observed between the iso-osmolar 0.3% HA group and the hypo-osmolar 0.18% HA group. In the iso-osmolar 0.1% HA and 0.15% HA, the difference between the products in each group was approximately 12 mOsm/L, and the CMC group had the smallest deviation among products, which was close to 300 mOsm/L. There was a significant difference of 305.57 ± 6.38 mOsm/L in the iso-osmolar 0.15% HA group, 293.44 ± 8.71 mOsm/L in the 0.1% HA group, and 285.67 ± 3.67 mOsm/L in the 0.3% HA group (p < 0.001). There was no significant difference in osmolarity between the iso-osmolar products containing HA and CMC (p = 0.117). Conclusions: There was a difference in osmolarity between the published and actual measured values of commercial artificial tears, and there was a difference in osmolality depending on the content of HA and the manufacturer.

    Original languageEnglish
    Pages (from-to)117-122
    Number of pages6
    JournalJournal of Korean Ophthalmological Society
    Volume59
    Issue number2
    DOIs
    Publication statusPublished - 2018 Feb

    Bibliographical note

    Funding Information:
    Department of Ophthalmology, Korea University Guro Hospital, #148 Gurodong-ro, Guro-gu, Seoul 08308, Korea Tel: 82-2-2626-1260, Fax: 82-2-857-8580 E-mail: [email protected] * This study was supported in part by Alumni of Department of Ophthalmology, Korea University College of Medicine.

    Publisher Copyright:
    © 2018 The Korean Ophthalmological Society.

    Keywords

    • Artificial tears
    • Dry eye
    • Osmolarity
    • TearLab®

    ASJC Scopus subject areas

    • Ophthalmology

    Fingerprint

    Dive into the research topics of 'Comparison of osmolarity of various artificial tears products commercially available in South Korea'. Together they form a unique fingerprint.

    Cite this