T1 - Comparison of the long-term clinical results of hydrophilic and hydrophobic acrylic intraocular lenses.
AU - Suh, Youngwoo
AU - Oh, Chunghoon
AU - Kim, Hyo Myung
PY - 2005/3
Y1 - 2005/3
N2 - This study was performed to compare the incidence of posterior capsular opacity (PCO) and refractive errors between hydrophilic (ACR6D, Corneal) and hydrophobic (MA60BM, AcrySof) acrylic intraocular lenses (IOLs) over a 3-year follow-up after phacoemulsification surgery. The patients with AcrySof implanted in one eye and Corneal in the other eye were categorized as Group 1 (n=28), while those with one or both eyes implanted with IOLs of the same kind were categorized as Group 2 (AcrySof, n=90; Corneal, n=95). Refractive errors were evaluated at 3 months and 3 years postoperatively. The incidence of visually significant PCO was investigated 3 years postoperatively. Postoperative refractive values at 3 months were not significantly different between the two groups. However, refractive values at 3 years were significantly different between two IOLs in both groups [AcrySof -0.37+/-0.43D, Corneal -0.62+/-0.58D in Group 1 (p=0.04); AcrySof -0.38+/-0.52, Corneal -0.68+/-0.54 in Group 2 (p<0.01)]. The incidence of visually significant PCO was 14% and 32% in Group 1, and 13% and 28% in Group 2, for the AcrySof and Corneal implants, respectively. The incidence of visually significant PCO of hydrophilic acrylic IOLs was higher than that of hydrophobic acrylic IOLs in the 3-year follow-up. The postoperative 3-year refractive value of Corneal showed myopic shift.
AB - This study was performed to compare the incidence of posterior capsular opacity (PCO) and refractive errors between hydrophilic (ACR6D, Corneal) and hydrophobic (MA60BM, AcrySof) acrylic intraocular lenses (IOLs) over a 3-year follow-up after phacoemulsification surgery. The patients with AcrySof implanted in one eye and Corneal in the other eye were categorized as Group 1 (n=28), while those with one or both eyes implanted with IOLs of the same kind were categorized as Group 2 (AcrySof, n=90; Corneal, n=95). Refractive errors were evaluated at 3 months and 3 years postoperatively. The incidence of visually significant PCO was investigated 3 years postoperatively. Postoperative refractive values at 3 months were not significantly different between the two groups. However, refractive values at 3 years were significantly different between two IOLs in both groups [AcrySof -0.37+/-0.43D, Corneal -0.62+/-0.58D in Group 1 (p=0.04); AcrySof -0.38+/-0.52, Corneal -0.68+/-0.54 in Group 2 (p<0.01)]. The incidence of visually significant PCO was 14% and 32% in Group 1, and 13% and 28% in Group 2, for the AcrySof and Corneal implants, respectively. The incidence of visually significant PCO of hydrophilic acrylic IOLs was higher than that of hydrophobic acrylic IOLs in the 3-year follow-up. The postoperative 3-year refractive value of Corneal showed myopic shift.
UR - http://www.scopus.com/inward/record.url?scp=20144371006&partnerID=8YFLogxK
U2 - 10.3341/kjo.2005.19.1.29
DO - 10.3341/kjo.2005.19.1.29
M3 - Article
C2 - 15929484
AN - SCOPUS:20144371006
SN - 1011-8942
VL - 19
SP - 29
EP - 33
JO - Korean journal of ophthalmology : KJO
JF - Korean journal of ophthalmology : KJO
IS - 1
ER -