TY - JOUR
T1 - Continuous immunosensing of myoglobin in human serum as potential companion diagnostics technique
AU - Kim, Dong Hyung
AU - Seo, Sung Min
AU - Cho, Hyun Mo
AU - Hong, Soon Jun
AU - Lim, Do Sun
AU - Paek, Se Hwan
N1 - Funding Information:
This research was supported by the Converging Research Center Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning, Korea (No. 2013K000249 ). This work was also supported by the BK21 plus program of the Ministry of Education, Republic of Korea .
PY - 2014/12/15
Y1 - 2014/12/15
N2 - To attain early diagnosis of acute myocardial infarction (AMI) with enhanced accuracy, continuous immunosensing has been investigated to measure myoglobin concentration in real-time. To this end, a capture antibody showing rapid reaction kinetics was immobilized on the surface of a surface plasmon resonance sensor. Three problems associated with the continuous sensing of myoglobin in human serum needed to be overcome: non-specific binding of the analyte, aggregation of serum components, and drift of the sensor baseline. Non-specific binding was controlled by pretreating the sample with a detergent mixture consisting of sodium dodecyl sulfate and P20, and adjusting the micelle size and net charge. Aggregation was managed by inactivating certain serum constituents through chelation of heavy metals. Baseline drift perceived in the sensorgram was able to be corrected by compensating for the slope calculated by a linear regression. Under the optimal conditions, the continuous sensor reproducibly traced the varying doses of myoglobin over about 8h with periodic one-point calibration every 3h. The dose-response curve of the sensor was linear with acceptable variations (CVs<4.91% in average) between the detection limit (31.0ng/mL) and about 2000ng/mL in the arithmetic scale (R2>0.98), covering the clinical concentration range. The immunosensor performance correlated with the Pathfast reference system (R2>0.98) and analytical consistency could be maintained for longer than a month if appropriately calibrated. Such immunosensing could be used as a companion diagnostic means along with real-time electrocardiographic measurement, significantly enhancing the sensitivity of AMI diagnosis and thereby enabling treatment at an early stage.
AB - To attain early diagnosis of acute myocardial infarction (AMI) with enhanced accuracy, continuous immunosensing has been investigated to measure myoglobin concentration in real-time. To this end, a capture antibody showing rapid reaction kinetics was immobilized on the surface of a surface plasmon resonance sensor. Three problems associated with the continuous sensing of myoglobin in human serum needed to be overcome: non-specific binding of the analyte, aggregation of serum components, and drift of the sensor baseline. Non-specific binding was controlled by pretreating the sample with a detergent mixture consisting of sodium dodecyl sulfate and P20, and adjusting the micelle size and net charge. Aggregation was managed by inactivating certain serum constituents through chelation of heavy metals. Baseline drift perceived in the sensorgram was able to be corrected by compensating for the slope calculated by a linear regression. Under the optimal conditions, the continuous sensor reproducibly traced the varying doses of myoglobin over about 8h with periodic one-point calibration every 3h. The dose-response curve of the sensor was linear with acceptable variations (CVs<4.91% in average) between the detection limit (31.0ng/mL) and about 2000ng/mL in the arithmetic scale (R2>0.98), covering the clinical concentration range. The immunosensor performance correlated with the Pathfast reference system (R2>0.98) and analytical consistency could be maintained for longer than a month if appropriately calibrated. Such immunosensing could be used as a companion diagnostic means along with real-time electrocardiographic measurement, significantly enhancing the sensitivity of AMI diagnosis and thereby enabling treatment at an early stage.
KW - Anti-serum aggregation
KW - Baseline drift correction
KW - Clinical sample pretreatment
KW - Continuous immunosensor
KW - Immunosensing performances
UR - http://www.scopus.com/inward/record.url?scp=84904063906&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2014.06.039
DO - 10.1016/j.bios.2014.06.039
M3 - Article
C2 - 25016254
AN - SCOPUS:84904063906
SN - 0956-5663
VL - 62
SP - 234
EP - 241
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
ER -