Abstract
The purpose of this article is to discuss the role of CEUS for screening of vascular complication in recipients admitted to ICU following LDLT, effect of microbubble contrast agent on Doppler phenomenon, CEUS technique, and illustrate CEUS findings in recipients with complication following LDLT. CEUS can enhance the role of US in the diagnosis of postoperative vascular complication in recipients following living donor liver transplantation at the bedside.
Original language | English |
---|---|
Pages (from-to) | 305-312 |
Number of pages | 8 |
Journal | Journal of Clinical Ultrasound |
Volume | 41 |
Issue number | 5 |
DOIs | |
Publication status | Published - 2013 Jun |
Keywords
- Contrast-enhanced ultrasound
- Living donor liver transplantation
- Vascular complication
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging