TY - JOUR
T1 - Current status of indwelling urinary catheter utilization and catheter-associated urinary tract infection throughout hospital wards in Korea
T2 - A multicenter prospective observational study
AU - Kim, Bongyoung
AU - Pai, Hyunjoo
AU - Choi, Won Suk
AU - Kim, Yeonjae
AU - Kweon, Ki Tae
AU - Kim, Hyun Ah
AU - Ryu, Seong Yeol
AU - Wie, Seong heon
AU - Kim, Jieun
N1 - Publisher Copyright:
© 2017 Kim et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2017/10
Y1 - 2017/10
N2 - To evaluate the frequency and appropriateness of indwelling urinary catheters (IUC) use and the incidence of catheter-associated urinary tract infections (CA-UTI), and explore the risk factors for CA-UTI in hospitals as a whole, we conducted a study. This study was divided into two parts; a point-prevalence study on Dec 12th 2012 and a prospective cohort study from Dec 13th 2012 to Jan 9th 2013 were performed in six hospitals in Korea. All hospitalized patients with newly-placed IUCs were enrolled and monitored weekly for 28 days after IUC placement. In the point-prevalence study, the IUCs were present in median 14.9/ 100 hospitalized patients (1Q 14, 3Q 16) across the six hospitals. In the prospective cohort study, the median IUC-days per patient was 5 (1Q 3, 3Q 10) and the median CA-UTI prevalence per 1,000 catheter days was 1.9 (1Q 0.7, 3Q 3.8) with significant inter-hospital variation. The proportion of patients with inappropriate IUC maintenance increased with number of IUC-days (8.5% on day 7, 9.4% on day 14, 16.3% on day 21, and 23.1% on day 28). Urinary output monitoring (23/36, 63.9%) was the most common indication for inappropriate use after 1 week of ICU placement. In multivariate analysis, IUC-days was significantly associated with the development of CA-UTI (odds ratio 1.122, 95% confidence interval 1.074–1.173, P< 0.001). IUC-days and CA-UTI rates vary between hospitals. IUC-days is a risk factor for CA-UTI, and is correlated with inappropriate use.
AB - To evaluate the frequency and appropriateness of indwelling urinary catheters (IUC) use and the incidence of catheter-associated urinary tract infections (CA-UTI), and explore the risk factors for CA-UTI in hospitals as a whole, we conducted a study. This study was divided into two parts; a point-prevalence study on Dec 12th 2012 and a prospective cohort study from Dec 13th 2012 to Jan 9th 2013 were performed in six hospitals in Korea. All hospitalized patients with newly-placed IUCs were enrolled and monitored weekly for 28 days after IUC placement. In the point-prevalence study, the IUCs were present in median 14.9/ 100 hospitalized patients (1Q 14, 3Q 16) across the six hospitals. In the prospective cohort study, the median IUC-days per patient was 5 (1Q 3, 3Q 10) and the median CA-UTI prevalence per 1,000 catheter days was 1.9 (1Q 0.7, 3Q 3.8) with significant inter-hospital variation. The proportion of patients with inappropriate IUC maintenance increased with number of IUC-days (8.5% on day 7, 9.4% on day 14, 16.3% on day 21, and 23.1% on day 28). Urinary output monitoring (23/36, 63.9%) was the most common indication for inappropriate use after 1 week of ICU placement. In multivariate analysis, IUC-days was significantly associated with the development of CA-UTI (odds ratio 1.122, 95% confidence interval 1.074–1.173, P< 0.001). IUC-days and CA-UTI rates vary between hospitals. IUC-days is a risk factor for CA-UTI, and is correlated with inappropriate use.
UR - http://www.scopus.com/inward/record.url?scp=85031019351&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0185369
DO - 10.1371/journal.pone.0185369
M3 - Article
C2 - 28991927
AN - SCOPUS:85031019351
SN - 1932-6203
VL - 12
JO - PLoS One
JF - PLoS One
IS - 10
M1 - e0185369
ER -