Design and performance investigation of a multi-pinhole collimator for a small field of view gamma imaging system

Jaekeon Bae, Seungbin Bae, Kisung Lee, Yong Choi, Yongkwon Kim, Jinhun Joung

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

The aim of this study is to design a collimator for a gamma imaging system that has a small-footprint, a fast-scan-time, and a organ-specific applicability. To achieve such features, the collimator must have a high resolution, a high sensitivity, and a gantry with a simple geometry. For ensuring high resolution and high sensitivity, we designed a multi-pinhole collimator. For realizing a simplified gantry, we carried out studies with limited angle reconstruction. On the designed multipinhole collimator has eight-pinholes, whose diameters are 2 mm. Limited-angle reconstruction has been conducted with angle intervals of 3, 6, 9, and 12° and with an angle coverage of 60, 90, 120, 150, and 180°. The reconstruction of an image was separately developed based on the ray-driven and voxel-driven methods in order to overcome the sampling problem and to reduce the amount of computation required. To evaluate the performance of the designed system, performed studies on three spherical phantoms and a heart phantom by using the Geant4 application for tomographic emission (GATE) simulation tool. The results showed that the full width at half maximum (FWHM) of the center source were 6.25 mm and 7.18 mm for single-pinhole and multi-pinhole collimators, respectively. Moreover, limited angle reconstruction resulted in a higher efficiency of the imaging system because it overcame the limitation of the gantry geometry. Limited-angle reconstruction was optimized at an angle coverage of 120° with an angle interval of 6°, then reconstructed image was shown a 12.18 mm FWHM. This suggests that the designed system needs only one-third the number of projections to acquire a reconstructed image with a slight degradation in image quality. This also suggests that our proposed multi-pinhole collimator is suitable for applications requiring a small-footprint, a fast-scan-time, and organ-specificity.

Original languageEnglish
Pages (from-to)970-975
Number of pages6
JournalJournal of the Korean Physical Society
Volume64
Issue number7
DOIs
Publication statusPublished - 2014

Bibliographical note

Funding Information:
This research was supported by the Basic Atomic Energy Research Institute (BAERI, 2010-0018616), the Nuclear R&D Program (2013M2A2A7029685), the Ministry of Education, Science and Technology (2010K001193) and a Korea University Grant. through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning of the Korean Government.

Keywords

  • Limited angle system
  • Multi-pinhole collimator
  • Nuclear medicine

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Fingerprint

Dive into the research topics of 'Design and performance investigation of a multi-pinhole collimator for a small field of view gamma imaging system'. Together they form a unique fingerprint.

Cite this