Diffusion tensor imaging of extraocular muscle using two-dimensional single-shot interleaved multiple inner volume imaging diffusion-weighted EPI at 3 tesla

Hyung Suk Seo, Seong Eun Kim, John Rose, J. Rock Hadley, Dennis L. Parker, Eun Kee Jeong

    Research output: Contribution to journalArticlepeer-review

    8 Citations (Scopus)

    Abstract

    Purpose To evaluate the feasibility of diffusion tensor imaging (DTI) for the medial and lateral rectus extraocular muscle (EOM) evaluation, to investigate the normal DTI parameters of the medial and lateral rectus EOM, and to compare with other skeletal muscle. Materials and Methods Seven multiple sclerosis patients and five normal subjects (M:F = 5:7, mean age = 31.6 ± 9.2) without EOM disorder were included. The orbital DTIs using 2D-ss-IMVI-DWEPI were scanned with b = 500 s/mm2 and 12 directions. The mean diffusivity (MD) and fractional anisotrophy (FA) of medial and lateral rectus EOMs in both orbits, and temporalis muscles were measured in regions of interest on two consecutive axial slices. Student t-test was performed to compare the mean apparent diffusion coefficient and FA values between medial and lateral rectus EOMs, and between EOMs and temporalis muscles. Results The MDs in medial (0.58 ± 0.18 × 10-3mm2/s) and lateral rectus EOMs (0.71 ± 0.18 × 10-3mm2/s) were significantly lower than temporalis muscle (0.84 ± 0.14 × 10-3 mm2/s) (P < 0.001, respectively). The MD in medial rectus EOM was significantly lower than lateral rectus EOM (P = 0.001). The FAs in medial (0.40 ± 0.05) and lateral rectus EOMs (0.40 ± 0.05) were significantly higher than temporalis muscle (0.25 ± 0.05) (P < 0.001, respectively). There was no significant difference between the FAs in medial and lateral rectus EOMs (P > 0.05). Conclusion The MDs of EOMs were lower and the FAs were higher than those of skeletal muscle. These are well correlated to the unique characteristics of EOMs. J. Magn. Reson. Imaging 2013;38:1162-1168. © 2013 Wiley Periodicals, Inc.

    Original languageEnglish
    Pages (from-to)1162-1168
    Number of pages7
    JournalJournal of Magnetic Resonance Imaging
    Volume38
    Issue number5
    DOIs
    Publication statusPublished - 2013 Nov

    Keywords

    • diffusion tensor imaging
    • muscle
    • orbit

    ASJC Scopus subject areas

    • Radiology Nuclear Medicine and imaging

    Fingerprint

    Dive into the research topics of 'Diffusion tensor imaging of extraocular muscle using two-dimensional single-shot interleaved multiple inner volume imaging diffusion-weighted EPI at 3 tesla'. Together they form a unique fingerprint.

    Cite this