T1 - Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound Biomicroscopy
AU - Oh, Jaeryung
AU - Shin, Hyung Ho
AU - Kim, Jun Heon
AU - Kim, Hyo Myung
AU - Song, Jong Suk
PY - 2007/9
Y1 - 2007/9
N2 - Purpose: To measure the ciliary sulcus diameters in 4 different axes and to determine the correlation with white-to-white distance. Design: Cross-sectional observational study. Participants: Fourteen normal volunteers with no evidence of ocular disease. Methods: Twenty-eight eyes were scanned using a 35-megahertz (MHz) ultrasound biomicroscopy (UBM) in sequential meridional scan planes at 45° increments. Horizontal white-to-white distance was measured using Orbscan IIz (Bausch & Lomb-Orbtek, Inc., Salt Lake City, UT). Main Outcome Measures: Ciliary sulcus diameter, anterior chamber diameter, white-to-white distance, and coefficient of variation. Results: The coefficient of variation for 35-MHz UBM was 0.90%. The mean diameters±standard deviations of ciliary sulci were 11.55±0.38 mm at 45°, 11.99±0.36 mm at 90°, 11.54±0.36 mm at 135°, and 11.32±0.40 mm at 180°. In all eyes, vertical diameters were greater than horizontal diameters. The mean difference between vertical and horizontal diameters was 0.67±0.26 mm (range, 0.36-1.13 mm), and this was statistically significant (P<0.001). Horizontal sulcus diameters and horizontal white-to-white distances were not correlated (r = 0.006; P = 0.976). Conclusions: The posterior chamber appears to have a vertically oval shape. The white-to-white technique is inaccurate at predicting the horizontal diameter of the ciliary sulcus. The 35-MHz UBM may provide a good means of measuring the ciliary sulcus diameter for the implantation of a posterior chamber phakic intraocular lens.
AB - Purpose: To measure the ciliary sulcus diameters in 4 different axes and to determine the correlation with white-to-white distance. Design: Cross-sectional observational study. Participants: Fourteen normal volunteers with no evidence of ocular disease. Methods: Twenty-eight eyes were scanned using a 35-megahertz (MHz) ultrasound biomicroscopy (UBM) in sequential meridional scan planes at 45° increments. Horizontal white-to-white distance was measured using Orbscan IIz (Bausch & Lomb-Orbtek, Inc., Salt Lake City, UT). Main Outcome Measures: Ciliary sulcus diameter, anterior chamber diameter, white-to-white distance, and coefficient of variation. Results: The coefficient of variation for 35-MHz UBM was 0.90%. The mean diameters±standard deviations of ciliary sulci were 11.55±0.38 mm at 45°, 11.99±0.36 mm at 90°, 11.54±0.36 mm at 135°, and 11.32±0.40 mm at 180°. In all eyes, vertical diameters were greater than horizontal diameters. The mean difference between vertical and horizontal diameters was 0.67±0.26 mm (range, 0.36-1.13 mm), and this was statistically significant (P<0.001). Horizontal sulcus diameters and horizontal white-to-white distances were not correlated (r = 0.006; P = 0.976). Conclusions: The posterior chamber appears to have a vertically oval shape. The white-to-white technique is inaccurate at predicting the horizontal diameter of the ciliary sulcus. The 35-MHz UBM may provide a good means of measuring the ciliary sulcus diameter for the implantation of a posterior chamber phakic intraocular lens.
UR - http://www.scopus.com/inward/record.url?scp=34548226462&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34548226462&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2006.12.018
DO - 10.1016/j.ophtha.2006.12.018
M3 - Article
C2 - 17822974
AN - SCOPUS:34548226462
SN - 0161-6420
VL - 114
SP - 1685
EP - 1688
JO - Ophthalmology
JF - Ophthalmology
IS - 9
ER -