Abstract
Background: Acinetobacter species are the leading cause of bloodstream infection (BSI), but their correct identification is challenging. We evaluated the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based VITEK MS (bioMérieux, France), and two automated systems, VITEK 2 (bioMérieux) and MicroScan (Siemens, USA) for identification of Acinetobacter BSI isolates.
Methods: A total of 187 BSI isolates recovered at a university hospital in Korea between 2010 and 2012 were analyzed. The identification results obtained using VITEK MS and two automated systems were compared with those of rpoB sequencing.
Results: Of 187 isolates analyzed, 176 were identified to the species level by rpoB sequencing: the Acinetobacter baumannii group (ABG; 101 A. baumannii, 43 A. nosocomialis, 10 A. pittii isolates) was most commonly identified (82.4%), followed by Acinetobacter genomic species 13BJ/14TU (5.3%), A. ursingii (2.1%), A. soli (2.1%), A. bereziniae (1.1%), and A. junii (1.1%). Correct identification rates to the species group (ABG) level or the species level was comparable among the three systems (VITEK MS, 90.3%; VITEK 2, 89.2%; MicroScan, 86.9%). However, VITEK MS generated fewer misidentifications (0.6%) than VITEK 2 (10.8%) and MicroScan (13.1%) (P0.001). In addition, VITEK MS demonstrated higher specificity (100%) for discrimination between ABG and non-ABG isolates than the other systems (both, 31.8%) (P0.001).
Conclusions: The VITEK MS system is superior to the VITEK 2 and MicroScan systems for identification of Acinetobacter BSI isolates, with fewer misidentifications and better discrimination between the ABG and non-ABG isolates.
| Original language | English |
|---|---|
| Pages (from-to) | 62-68 |
| Number of pages | 7 |
| Journal | Annals of laboratory medicine |
| Volume | 35 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 2015 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© The Korean Society for Laboratory Medicine.
Keywords
- Acinetobacter
- Identification
- MicroScan
- VITEK 2
- VITEK MS
ASJC Scopus subject areas
- Clinical Biochemistry
- Biochemistry, medical
Fingerprint
Dive into the research topics of 'Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry-based VITEK MS system for the identification of acinetobacter species from blood cultures: Comparison with VITEK 2 and MicroScan systems'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS