Feasibility of obtaining quantitative 3-dimensional information using conventional endoscope: A pilot study

Jong Jin Hyun, Hoon Jai Chun, Bora Keum, Yeon Seok Seo, Yong Sik Kim, Yoon Tae Jeen, Hong Sik Lee, Soon Ho Um, Chang Duck Kim, Ho Sang Ryu, Jong Wook Lim, Dong Gi Woo, Young Joong Kim, Myo Taeg Lim

    Research output: Contribution to journalArticlepeer-review

    7 Citations (Scopus)

    Abstract

    Background/Aims: Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods: Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results: The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions: It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object.

    Original languageEnglish
    Pages (from-to)182-188
    Number of pages7
    JournalClinical Endoscopy
    Volume45
    Issue number3
    DOIs
    Publication statusPublished - 2012

    Keywords

    • 3-dimensional imaging
    • Distortion
    • Endoscopes
    • Epipolar geometry

    ASJC Scopus subject areas

    • Medicine (miscellaneous)
    • Radiology Nuclear Medicine and imaging
    • Gastroenterology

    Fingerprint

    Dive into the research topics of 'Feasibility of obtaining quantitative 3-dimensional information using conventional endoscope: A pilot study'. Together they form a unique fingerprint.

    Cite this