Impact of chronic outward force on arterial responses of proximal and distal of long superficial femoral artery stent

Hu Li, Seung Woon Rha, Byoung Geol Choi, Se Yeon Choi, Sang Ki Moon, Won Young Jang, Woohyeun Kim, Ji Hun Ahn, Sang Ho Park, Woong Gil Choi, Rui Feng Yang, Wen Wei Bai, Cheol Ung Choi, Yang gi Ryu, Man Jong Baek, Dong Joo Oh

    Research output: Contribution to journalArticlepeer-review

    6 Citations (Scopus)

    Abstract

    Background: Self-expanding nitinol stent (SENS) implantation is commonly oversized in the superficial femoral artery (SFA), and leads to chronic outward force (COF) and in-stent restenosis (ISR). This study aimed to investigate the impact of COF of oversizing SENS on ISR of SFA. Methods: In patients with implanted SENS in SFA, intimal hyperplasia especially between proximal segment and distal segment was evaluated by quantitative angiography, and the impact of COF on mid-term angiographic outcomes was investigated. In addition, porcine model with implanted SENS was used to evaluate the impact of COF on angiographic and histopathologic outcomes at 1 month. Excised stented arteries were evaluated by histopathologic analysis. Results: We analyzed 65 SENS in 61 patients with follow-up angiography at 6 months to 1 year. The baseline diameter was 6.8 ± 0.71 mm and length were 97.0 ± 33.8 mm for the SENS. The ratio of the diameter of the stent to the reference vessel was 1.3 ± 0.24 at the proximal portion and 1.53 ± 0.27 at the distal portion (P < 0.001). In the long SFA stent, stent-to-vessel ratio was significantly higher in the distal stent than in the proximal stent (1.3 ± 0.2 vs. 1.55 ± 0.25, P = 0.001). ISR incidence was higher at the distal stent (37.3% vs 52.6%, P = 0.029). All 11 pigs survived for 4 weeks after SENS implantation. The vessel diameter was 4.04 ± 0.40 mm (control group) vs 4.45 ± 0.63 mm (oversized group), and the implanted stent diameter was 5.27 ± 0.46 mm vs. 7.18 ± 0.4 mm (P = 0.001). The stent-to-vessel diameter ratio was 1.31 ± 0.12 versus 1.63 ± 0.20 (P < 0.001). After 4 weeks, restenosis % was 29.5 ± 12.9% versus 46.8 ± 21.5% (P = 0.016). The neointimal area was 5.37 ± 1.15 mm2 vs. 8.53 ± 5.18 mm2 (P = 0.05). The restenosis % was 39.34 ± 8.53% versus 63.97 ± 17.1% (P = 0.001). Conclusions: COF is an important cause of restenosis in the distal portion of the SFA stent. Optimal sizing of the SFA stent is important to reduce the incidence of restenosis. Therefore, COF was an important factor of restenosis following distal SFA stenting.

    Original languageEnglish
    Article number323
    JournalBMC Cardiovascular Disorders
    Volume21
    Issue number1
    DOIs
    Publication statusPublished - 2021 Dec

    Bibliographical note

    Publisher Copyright:
    © 2021, The Author(s).

    Keywords

    • Chronic outward force
    • Histomorphometry
    • Self-expanding nitinol stents
    • Stent oversizing
    • Superficial femoral artery

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine

    Fingerprint