TY - GEN
T1 - Influence of blade pass frequency vibrations on MCSA-based rotor fault detection of induction motors
AU - Park, Yonghyun
AU - Jeong, Myung
AU - Lee, Sang Bin
AU - Antonino-Daviu, Jose Alfonso
AU - Teska, Mike
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016
Y1 - 2016
N2 - Motor current signature analysis (MCSA) has recently become widespread in industry for on-line detection of rotor cage faults in induction motors for preventing forced outages. Although it can provide low cost, remote monitoring of rotor faults, cases of false indications have been reported, where the causes of some false indications are still unknown. It is shown for the first time in this work that high-amplitude blade pass frequency (BPF) vibrations produced in pumps, fans, or compressors can cause false rotor fault indications, if the number of motor poles is an integer multiple of the number of blades. The influence of BPF vibration on MCSA based rotor fault detection is analyzed, and it is shown that the interaction between BPF vibration and rotor faults can produce false positive and negative fault indications. Alternative test methods capable of separating the influence of the BPF vibration and rotor faults are suggested for avoiding false MCSA alarms. The claims made in the paper are verified experimentally on a custom-built 380 V induction motor-centrifugal pump system setup.
AB - Motor current signature analysis (MCSA) has recently become widespread in industry for on-line detection of rotor cage faults in induction motors for preventing forced outages. Although it can provide low cost, remote monitoring of rotor faults, cases of false indications have been reported, where the causes of some false indications are still unknown. It is shown for the first time in this work that high-amplitude blade pass frequency (BPF) vibrations produced in pumps, fans, or compressors can cause false rotor fault indications, if the number of motor poles is an integer multiple of the number of blades. The influence of BPF vibration on MCSA based rotor fault detection is analyzed, and it is shown that the interaction between BPF vibration and rotor faults can produce false positive and negative fault indications. Alternative test methods capable of separating the influence of the BPF vibration and rotor faults are suggested for avoiding false MCSA alarms. The claims made in the paper are verified experimentally on a custom-built 380 V induction motor-centrifugal pump system setup.
UR - http://www.scopus.com/inward/record.url?scp=85015367455&partnerID=8YFLogxK
U2 - 10.1109/ECCE.2016.7855199
DO - 10.1109/ECCE.2016.7855199
M3 - Conference contribution
AN - SCOPUS:85015367455
T3 - ECCE 2016 - IEEE Energy Conversion Congress and Exposition, Proceedings
BT - ECCE 2016 - IEEE Energy Conversion Congress and Exposition, Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2016 IEEE Energy Conversion Congress and Exposition, ECCE 2016
Y2 - 18 September 2016 through 22 September 2016
ER -