Abstract
This paper describes integrated membrane systems (IMS) performance at five sites, which employed chloramination, coagulation, sedimentation and filtration, GAC and/or size exclusion membrane filtration to enhance IMS productivity. Results indicate that effects of fouling are site specific, biological>organic>particle>precipitative fouling and all fouling mechanisms must be controlled for satisfactory IMS productivity for surface water sources.
Original language | English |
---|---|
Journal | NACE - International Corrosion Conference Series |
Volume | 2000-March |
Publication status | Published - 2000 |
Externally published | Yes |
Event | Corrosion 2000 - Orlando, United States Duration: 2000 Mar 26 → 2000 Mar 31 |
Bibliographical note
Publisher Copyright:© 2000 by NACE International.
ASJC Scopus subject areas
- General Chemistry
- General Chemical Engineering
- General Materials Science