TY - GEN
T1 - Intravaginal packing effects of CT-guided intracavitary radiotherapy for cervical cancer
AU - Lee, Doo Hyun
AU - Cho, Jung Keun
AU - Shin, Kyung Hwan
AU - Shin, Dongho
AU - Yoon, Myonggeun
AU - Park, Sung Yong
AU - Lee, Se Byeong
AU - Kim, Joo Young
AU - Cho, Kwan Ho
AU - Suh, Tae Suk
PY - 2007
Y1 - 2007
N2 - Ten plans for Ir 192 high-dose-rate ICR after 30-40 Gy external beam radiotherapy were investigated. The ICR prescription dose for an each insertion was 4 or 5 Gy to point A, twice weekly, and the total dose of ICR ranged from 24 to 30 Gy (median, 24). A fractional 100% dose was prescribed to point A. Two sets of CT images before and after packing were acquired at the first ICR session with artifactfree applicators in place. The International Commission on Radiation Units and Measurements Report 38 (ICRU-38) rectal and bladder points, and the percentage of volumes receiving 50%, 80%, and 100% of the prescribed dose were also analyzed and compared. Conventional point A plans were performed. The mean values of the bladder and rectal ICRU- 38 point doses before packing, 109.93% and 117.80%, were decreased after packing to 98.85% and 94.93%, respectively, with the difference being marginally significant (p=0.013) (Edthis p value is not significant at all). The maximum point doses of the bladder and rectum were decreased by 20.12% and 16.01%, respectively. The mean-volume fractions of the bladder receiving 50%, 80%, and 100% of the reference dose were decreased by 8.29%, 4.48% and 2.64%, while the decrease of the mean-volume fractions for the rectum were relatively small at 4.44%, 1.52% and 1.20%, respectively. However, this reduction was not significant based on a p value of about 0.15~0.81. While the dose at the reference point was decreased significantly due to the packing effects, the presence or absence of packing had little effect on volumetric doses because the volumes enlarged by the packing effects were relatively small compared to the volume of the entire bladder and rectum itself. The packing is still needed as it could reduce the complications caused by the high point dose and decrease the maximum dose.
AB - Ten plans for Ir 192 high-dose-rate ICR after 30-40 Gy external beam radiotherapy were investigated. The ICR prescription dose for an each insertion was 4 or 5 Gy to point A, twice weekly, and the total dose of ICR ranged from 24 to 30 Gy (median, 24). A fractional 100% dose was prescribed to point A. Two sets of CT images before and after packing were acquired at the first ICR session with artifactfree applicators in place. The International Commission on Radiation Units and Measurements Report 38 (ICRU-38) rectal and bladder points, and the percentage of volumes receiving 50%, 80%, and 100% of the prescribed dose were also analyzed and compared. Conventional point A plans were performed. The mean values of the bladder and rectal ICRU- 38 point doses before packing, 109.93% and 117.80%, were decreased after packing to 98.85% and 94.93%, respectively, with the difference being marginally significant (p=0.013) (Edthis p value is not significant at all). The maximum point doses of the bladder and rectum were decreased by 20.12% and 16.01%, respectively. The mean-volume fractions of the bladder receiving 50%, 80%, and 100% of the reference dose were decreased by 8.29%, 4.48% and 2.64%, while the decrease of the mean-volume fractions for the rectum were relatively small at 4.44%, 1.52% and 1.20%, respectively. However, this reduction was not significant based on a p value of about 0.15~0.81. While the dose at the reference point was decreased significantly due to the packing effects, the presence or absence of packing had little effect on volumetric doses because the volumes enlarged by the packing effects were relatively small compared to the volume of the entire bladder and rectum itself. The packing is still needed as it could reduce the complications caused by the high point dose and decrease the maximum dose.
KW - Intracavitary radiotherapy
KW - Intravaginal packing
UR - http://www.scopus.com/inward/record.url?scp=84958236388&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84958236388&partnerID=8YFLogxK
U2 - 10.1007/978-3-540-36841-0_431
DO - 10.1007/978-3-540-36841-0_431
M3 - Conference contribution
AN - SCOPUS:84958236388
SN - 9783540368397
T3 - IFMBE Proceedings
SP - 1742
EP - 1745
BT - IFMBE Proceedings
A2 - Kim, Sun I.
A2 - Suh, Tae Suk
PB - Springer Verlag
T2 - 10th World Congress on Medical Physics and Biomedical Engineering, WC 2006
Y2 - 27 August 2006 through 1 September 2006
ER -