Abstract
In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with 45° and 60° bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.
Original language | English |
---|---|
Pages (from-to) | 313-318 |
Number of pages | 6 |
Journal | Transactions of the Korean Society of Mechanical Engineers, A |
Volume | 36 |
Issue number | 3 |
DOIs | |
Publication status | Published - 2012 Mar |
Keywords
- Bend angle
- Bending
- CANDU
- Circular wall-thinnings
- Feeder pipe
- Internal pressure
- Limit load
ASJC Scopus subject areas
- Mechanical Engineering