Nonspecific adsorption minimized nanomechanical immunoassay for application to assay using the real sample

Kyo Seon Hwang, Sang Myung Lee, Byung Hak Cha, Sang Kyung Kim, Jung Ho Park, Tae Song Kim

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Abstract

    We report an application feasibility of the dynamic microcantilever to detect the specific protein in human serum. The mechanical response (i.e. resonant frequency) change of functionalized dynamic microcantilever generated by biomolecular interactions allows one to detect the biomolecules of small amount without labeling process. We implemented the label-free detection of PSA in human serum like sample (protein mixture sample). The range of detected PSA was 1 and 10 ng/ml in clinical concentration range. It is suggest that the dynamic microcantilever enables one to apply the sensitive label-free detection of disease marker proteins in a real human sample.

    Original languageEnglish
    Title of host publicationProceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007
    EditorsJean-Louis Viovy, Patrick Tabeling, Stephanie Descroix, Laurent Malaquin
    PublisherChemical and Biological Microsystems Society
    Pages1267-1269
    Number of pages3
    ISBN (Electronic)9780979806407
    Publication statusPublished - 2007
    Event11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007 - Paris, France
    Duration: 2007 Oct 72007 Oct 11

    Publication series

    NameProceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007

    Conference

    Conference11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007
    Country/TerritoryFrance
    CityParis
    Period07/10/707/10/11

    Bibliographical note

    Funding Information:
    The authors are grateful for the financial support by Intelligent Microsystem Center sponsored by Korea iM nistry of Science and Technology as a part of the 21 st century’s Frontier &DR Projects (Grant SM -01-133-01) and National Core eR search Center for Nanomedical Technology sponsored by KOSEF (Grant 1R 5-2004-024-00000-0).

    Publisher Copyright:
    © 2007 CBMS.

    Keywords

    • Clinical range
    • Microcantilever
    • PSA
    • Real sample

    ASJC Scopus subject areas

    • Chemical Engineering (miscellaneous)
    • Bioengineering

    Fingerprint

    Dive into the research topics of 'Nonspecific adsorption minimized nanomechanical immunoassay for application to assay using the real sample'. Together they form a unique fingerprint.

    Cite this