Abstract
A new hybrid damper which combines a friction damper and steel strip damper is proposed for improving the seismic performance of structures at multiple levels of ground motion. In order to investigate the combined behavior of the proposed damper, quasi-static cyclic tests were carried out on ten specimens. Experimental results demonstrated that hysteretic response was stable, and multi-phased behavior (i.e., activation of two different kinds of dampers) functioned as intended. However, depending on the type of strip damper applied, the behavior and failure modes showed distinct differences due to rotational motion induced during combined behavior deformation and energy dissipation capacities were enhanced when a strip damper with adequate out-of-plane stiffness was applied. Furthermore, numerical analysis based on both material strength and expected strength well represented behavioral characteristics of the damper, and dissipated energy was reliably predicted. It is expected that the proposed analytical model can be practically applied to predict the performance of structures strengthened by the hybrid damper.
Original language | English |
---|---|
Pages (from-to) | 75-92 |
Number of pages | 18 |
Journal | Engineering Structures |
Volume | 114 |
DOIs | |
Publication status | Published - 2016 May 1 |
Keywords
- Combined behavior
- Cyclic loading
- Energy dissipation
- Friction damper
- Hybrid damper
- Metallic damper
- Out-of-plane behavior
- Passive control system
ASJC Scopus subject areas
- Civil and Structural Engineering