TY - JOUR
T1 - Olfactory detection of toluene by detection rats for potential screening of lung cancer
AU - Oh, Yunkwang
AU - Kwon, Oh Seok
AU - Min, Sun Seek
AU - Shin, Yong Beom
AU - Oh, Min Kyu
AU - Kim, Moonil
N1 - Funding Information:
This research was funded by the BioNano Health-Guard Research Center as Global Frontier Project [H-GUARD 2016941340], the Bio & Medical Technology Development Program of the National Research Foundation (NRF) funded by the Ministry of Science & ICT [2021M3A9I5021439] and the Korea Research Institute of Bioscience and Biotechnology (KRIBB) Initiative Research Program [KGM9952112].
Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/5/1
Y1 - 2021/5/1
N2 - Early detection is critical to successfully eradicating a variety of cancers, so the development of a new cancer primary screening system is essential. Herein, we report an animal nose sensor system for the potential primary screening of lung cancer. To establish this, we developed an odor discrimination training device based on operant conditioning paradigms for detection of toluene, an odor indicator component of lung cancer. The rats (N = 15) were trained to jump onto a floating ledge in response to toluene-spiked breath samples. Twelve rats among 15 trained rats reached performance criterion in 12 consecutive successful tests within a given set, or over 12 sets, with a success rate of over 90%. Through a total of 1934 tests, the trained rats (N = 3) showed excellent performance for toluene detection with 82% accuracy, 83% sensitivity, 81% specificity, 80% positive predictive value (PPV) and 83% negative predictive value (NPV). The animals also acquired considerable performance for odor discrimination even in rigorous tests, validating odor specificity. Since environmental and long-term stability are important factors that can influence the sensing results, the performance of the trained rats was studied under specified temperature (20, 25, and 30◦C) and humidity (30%, 45%, and 60% RH) conditions, and monitored over a period of 45 days. At given conditions of temperature and humidity, the animal sensors showed an average accuracy within a deviation range of ±10%, indicating the excellent environmental stability of the detection rats. Surprisingly, the trained rats did not differ in retention of last odor discrimination when tested 45 days after training, denoting that the rats’ memory for trained odor is still available over a long period of time. When taken together, these results indicate that our odor discrimination training system can be useful for non-invasive breath testing and potential primary screening of lung cancer.
AB - Early detection is critical to successfully eradicating a variety of cancers, so the development of a new cancer primary screening system is essential. Herein, we report an animal nose sensor system for the potential primary screening of lung cancer. To establish this, we developed an odor discrimination training device based on operant conditioning paradigms for detection of toluene, an odor indicator component of lung cancer. The rats (N = 15) were trained to jump onto a floating ledge in response to toluene-spiked breath samples. Twelve rats among 15 trained rats reached performance criterion in 12 consecutive successful tests within a given set, or over 12 sets, with a success rate of over 90%. Through a total of 1934 tests, the trained rats (N = 3) showed excellent performance for toluene detection with 82% accuracy, 83% sensitivity, 81% specificity, 80% positive predictive value (PPV) and 83% negative predictive value (NPV). The animals also acquired considerable performance for odor discrimination even in rigorous tests, validating odor specificity. Since environmental and long-term stability are important factors that can influence the sensing results, the performance of the trained rats was studied under specified temperature (20, 25, and 30◦C) and humidity (30%, 45%, and 60% RH) conditions, and monitored over a period of 45 days. At given conditions of temperature and humidity, the animal sensors showed an average accuracy within a deviation range of ±10%, indicating the excellent environmental stability of the detection rats. Surprisingly, the trained rats did not differ in retention of last odor discrimination when tested 45 days after training, denoting that the rats’ memory for trained odor is still available over a long period of time. When taken together, these results indicate that our odor discrimination training system can be useful for non-invasive breath testing and potential primary screening of lung cancer.
KW - Animal nose
KW - Detection rat
KW - Odor detection
KW - Olfactory behavior
UR - http://www.scopus.com/inward/record.url?scp=85104559804&partnerID=8YFLogxK
U2 - 10.3390/s21092967
DO - 10.3390/s21092967
M3 - Article
C2 - 33922694
AN - SCOPUS:85104559804
SN - 1424-8220
VL - 21
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 9
M1 - 2967
ER -