Operation of a multigap resistive plate chamber in the streamer mode

M. S. Ryu, B. Hong, K. S. Lee, S. Park, K. S. Sim

    Research output: Contribution to journalArticlepeer-review

    10 Citations (Scopus)

    Abstract

    We present the design, the building procedure, and the test results for a prototype multigap resistive plate chamber (RPC) using normal glass plates as the resistive material. A detection efficiency of almost 100 % and a time resolution of about 340 ps were achieved at the operational plateau region, which extended more than 400 V regardless of the discriminator threshold. These results open a possibility that the multigap RPC can be used for charged particle identification in nuclear-collision experiments.

    Original languageEnglish
    Pages (from-to)905-908
    Number of pages4
    JournalJournal of the Korean Physical Society
    Volume47
    Issue number5
    Publication statusPublished - 2005 Nov

    Keywords

    • Efficiency
    • Multigap RFC
    • Streamer mode
    • Time resolution

    ASJC Scopus subject areas

    • General Physics and Astronomy

    Fingerprint

    Dive into the research topics of 'Operation of a multigap resistive plate chamber in the streamer mode'. Together they form a unique fingerprint.