Abstract
We have been developing the trigger system using the Electromagnetic Calorimeter(ECL) which is one of sub-detectors in the Belle II experiment. The ECL trigger system is based on Trigger Cell(TC), and each TC consists of 16 crystals. To make a decision of physics events at an online trigger level, energy deposit in the TC and the event timing are required. Therefore, we have performed the TC energy calibration by a method of comparing the ECL trigger data with the ECL data, and the TC time offset calibration by using a least χ2 algorithm. We report the calibration method and performance using cosmic ray data.
Original language | English |
---|---|
Article number | 804 |
Journal | Proceedings of Science |
Volume | 340 |
Publication status | Published - 2019 |
Event | 39th International Conference on High Energy Physics, ICHEP 2018 - Seoul, Korea, Republic of Duration: 2018 Jul 4 → 2018 Jul 11 |
Bibliographical note
Publisher Copyright:© owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).
ASJC Scopus subject areas
- General