TY - JOUR
T1 - Performance comparison of platelet function analyzers in cardiology patients
T2 - VerifyNow and Anysis-200 aspirin assays
AU - Chung, Young Hak
AU - Lee, Kyung Ah
AU - Cho, Minhee
AU - Shin, Sehyun
AU - Lee, Byoung Kwon
N1 - Funding Information:
This research was supported by the Korean Health Technology R&D Project, Ministry of Health and Welfare (no. HI14C0670).
Publisher Copyright:
© 2020-IOS Press and the authors. All rights reserved.
PY - 2020
Y1 - 2020
N2 - BACKGROUND: Analysis of responsiveness to antiplatelet therapy is crucial in the management of patients with cardiovascular diseases. OBJECTIVE: This study aimed to evaluate a new platelet function analysis system (Anysis-200) and to compare it with VerifyNow (Accumetrics, San Diego, CA, USA) in cardiology patients. METHODS: Overall, 125 citrated blood samples were collected from 85 cardiology patients referred for platelet function testing. In Anysis-200, platelet function was measured as blood migration distance (MD) until clogging of flow passage, which is comparable to aspirin resistance units obtained using VerifyNow. The two devices were simultaneously used and compared. RESULTS: The MDs before and after taking aspirin were 175±51 and 247±27 mm, respectively (p < 0.0001). Compared with VerifyNow (reference), the sensitivity and specificity of Anysis-200 was 91.5% and 75.5%, respectively (area under the curve, 0.829). Further, the true positive rate in patients newly taking aspirin was 85% for VerifyNow and 92.5% for Anysis-200, respectively. The Cohen's kappa coefficient between the two devices was 0.682, indicating a relatively high agreement. CONCLUSIONS: Anysis-200, a novel system for assessing platelet aggregation, has accuracy and precision equivalent to that of, and significant agreement with, VerifyNow. Anysis-200 may be useful in screening patients with abnormal platelet reactivity and aspirin nonresponsiveness.
AB - BACKGROUND: Analysis of responsiveness to antiplatelet therapy is crucial in the management of patients with cardiovascular diseases. OBJECTIVE: This study aimed to evaluate a new platelet function analysis system (Anysis-200) and to compare it with VerifyNow (Accumetrics, San Diego, CA, USA) in cardiology patients. METHODS: Overall, 125 citrated blood samples were collected from 85 cardiology patients referred for platelet function testing. In Anysis-200, platelet function was measured as blood migration distance (MD) until clogging of flow passage, which is comparable to aspirin resistance units obtained using VerifyNow. The two devices were simultaneously used and compared. RESULTS: The MDs before and after taking aspirin were 175±51 and 247±27 mm, respectively (p < 0.0001). Compared with VerifyNow (reference), the sensitivity and specificity of Anysis-200 was 91.5% and 75.5%, respectively (area under the curve, 0.829). Further, the true positive rate in patients newly taking aspirin was 85% for VerifyNow and 92.5% for Anysis-200, respectively. The Cohen's kappa coefficient between the two devices was 0.682, indicating a relatively high agreement. CONCLUSIONS: Anysis-200, a novel system for assessing platelet aggregation, has accuracy and precision equivalent to that of, and significant agreement with, VerifyNow. Anysis-200 may be useful in screening patients with abnormal platelet reactivity and aspirin nonresponsiveness.
KW - Anysis-200 analyzer
KW - Platelet function
KW - VerifyNow
KW - aspirin
UR - http://www.scopus.com/inward/record.url?scp=85088318833&partnerID=8YFLogxK
U2 - 10.3233/CH-200822
DO - 10.3233/CH-200822
M3 - Article
C2 - 32538826
AN - SCOPUS:85088318833
SN - 1386-0291
VL - 76
SP - 33
EP - 42
JO - Clinical Hemorheology and Microcirculation
JF - Clinical Hemorheology and Microcirculation
IS - 1
ER -