Abstract
In the present study, we suggest a new way to reactivate performance of direct formic acid fuel cell (DFAFC) and explain its mechanism by employing electrochemical analyses like chronoamperometry (CA) and cyclic voltammogram (CV). For the evaluation of DFAFC perforamce, palladium (Pd) and platinum (Pt) are used as anode and cathode catalysts, respectively, and are applied to a Nafion membrane by catalyst-coated membrane spraying. After long DFAFC operation performed at 0.2 and 0.4 V and then CV test, DFAFC performance is better than its initial performance. It is attributed to dissolution of anode Pd into Pd 2+. By characterizations like TEM, Z-potential, CV and electrochemical impedance spectroscopy, it is evaluated that such dissolved Pd 2+ ions lead to (1) increase in the electrochemically active surface by reduction in Pd particle size and its improved redistribution and (2) increment in the total oxidation charge by fast reaction rate of the Pd dissolution reaction.
Original language | English |
---|---|
Pages (from-to) | 2539-2545 |
Number of pages | 7 |
Journal | Bulletin of the Korean Chemical Society |
Volume | 33 |
Issue number | 8 |
DOIs | |
Publication status | Published - 2012 Aug 20 |
Keywords
- Direct formic acid fuel cell
- Electrochemical impedance spectroscopy
- Palladium dissolution
- Palladium recovery
ASJC Scopus subject areas
- Chemistry(all)