TY - JOUR
T1 - Potentiometric multichannel cytometer microchip for high-throughput microdispersion analysis
AU - Kim, Junhoi
AU - Kim, Eun Geun
AU - Bae, Sangwook
AU - Kwon, Sunghoon
AU - Chun, Honggu
PY - 2013/1/2
Y1 - 2013/1/2
N2 - The parallelization of microfluidic cytometry is expected to lead to considerably enhanced throughput enabling point-of-care diagnosis. In this article, the development of a microfluidic potentiometric multichannel cytometer is presented. Parallelized microfluidic channels sharing a fluid path inevitably suffer from interchannel signal crosstalk that results from electrical coupling within the microfluidic channel network. By employing three planar electrodes within a single detection channel, we electrically decoupled each channel unit, thereby enabling parallel analysis by using a single cytometer microchip with multiple microfluidic channels. The triple-electrode configuration is validated by analyzing the size and concentration of polystyrene microbeads (diameters: 1.99, 2.58, 3, and 3.68 μm; concentration range: ∼2 × 105 mL-1 to ∼1 × 10 7 mL-1) and bacterial microdispersion samples (Bacillus subtilis, concentration range: ∼4 × 105 CFU mL-1 to ∼3 × 106 CFU mL-1). Crosstalk-free parallelized analysis is then demonstrated using a 16-channel potentiometric cytometer (maximum cross-correlation coefficients |r|: < 0.13 in all channel combinations). A detection throughput of ∼48 000 s-1 was achieved; the throughout can be easily increased with the degree of parallelism of a single microchip without additional technical complexities. Therefore, this methodology should enable high-throughput and low-cost cytometry.
AB - The parallelization of microfluidic cytometry is expected to lead to considerably enhanced throughput enabling point-of-care diagnosis. In this article, the development of a microfluidic potentiometric multichannel cytometer is presented. Parallelized microfluidic channels sharing a fluid path inevitably suffer from interchannel signal crosstalk that results from electrical coupling within the microfluidic channel network. By employing three planar electrodes within a single detection channel, we electrically decoupled each channel unit, thereby enabling parallel analysis by using a single cytometer microchip with multiple microfluidic channels. The triple-electrode configuration is validated by analyzing the size and concentration of polystyrene microbeads (diameters: 1.99, 2.58, 3, and 3.68 μm; concentration range: ∼2 × 105 mL-1 to ∼1 × 10 7 mL-1) and bacterial microdispersion samples (Bacillus subtilis, concentration range: ∼4 × 105 CFU mL-1 to ∼3 × 106 CFU mL-1). Crosstalk-free parallelized analysis is then demonstrated using a 16-channel potentiometric cytometer (maximum cross-correlation coefficients |r|: < 0.13 in all channel combinations). A detection throughput of ∼48 000 s-1 was achieved; the throughout can be easily increased with the degree of parallelism of a single microchip without additional technical complexities. Therefore, this methodology should enable high-throughput and low-cost cytometry.
UR - http://www.scopus.com/inward/record.url?scp=84871775828&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84871775828&partnerID=8YFLogxK
U2 - 10.1021/ac302905x
DO - 10.1021/ac302905x
M3 - Article
C2 - 23181566
AN - SCOPUS:84871775828
SN - 0003-2700
VL - 85
SP - 362
EP - 368
JO - Analytical chemistry
JF - Analytical chemistry
IS - 1
ER -