Prevalence and predictors of clinically relevant atrial high-rate episodes in patients with cardiac implantable electronic devices

  • Min Kim
  • , Tae Hoon Kim
  • , Hee Tae Yu
  • , Eue Keun Choi
  • , Hyung Seob Park
  • , Junbeom Park
  • , Young Soo Lee
  • , Ki Woon Kang
  • , Jaemin Shim
  • , Jung Hoon Sung
  • , Il Young Oh*
  • , Boyoung Joung*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Background and Objectives: Atrial high-rate episodes (AHREs) can be continuously detected by cardiovascular implantable electronic devices (CIEDs); however, the predictors of clinically relevant AHREs are unclear. Methods: This prospective multicenter study monitored 816 patients (median age 73 years, 40.4% male) without atrial fibrillation (AF) from September 2017 to July 2020. AHREs was defined as a programmed atrial detection rate >220 beats/min. The reference values of 6 minutes and 6 hours were set to analyze clinical implication of AHREs based on previously published data that the 6 minutes excluded most episodes of oversensing. Results: During a median follow-up of 18 months (interquartile interval 9–26 months), AHREs with the longest durations of >15 seconds, >6 minutes, and >6 hours and clinically documented AF by electrocardiography were noted in 246 (30.1%), 112 (13.7%), 49 (6.0%), and 24 (2.9%) patients, respectively. Among patients developing AHREs >6 minutes, 102 (91.1%) of 112 patients were identified at the 6-month visit. Patients with AHREs >6 minutes had higher proportions of sick sinus syndrome, subjects with atrial premature beat >1% on Holter monitoring, and larger left atrium (LA) size than patients with AHREs ≤6 minutes. Multivariable logistic regression analysis showed that LA diameter >41 mm (odds ratio [OR], 2.08; 95% confidence interval [95% CI], 1.25–3.45), and sick sinus syndrome (OR, 3.22; 95% CI, 1.91–5.43) were associated with AHREs >6 minutes. Conclusions: In patients with LA diameter >41 mm, and sick sinus syndrome before CIEDs implantation is associated with risk of developing AHREs >6 minutes.

Original languageEnglish
Article numbere9 Received: Sep 2, 2020
JournalKorean Circulation Journal
Volume51
DOIs
Publication statusPublished - 2020 Dec 16

Bibliographical note

Publisher Copyright:
Copyright © 2021. The Korean Society of Cardiology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Keywords

  • Arrhythmia
  • Left atrium
  • Pacemaker, artificial
  • Sick sinus syndrome

ASJC Scopus subject areas

  • Internal Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Prevalence and predictors of clinically relevant atrial high-rate episodes in patients with cardiac implantable electronic devices'. Together they form a unique fingerprint.

Cite this