Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence

  • Xiaoming Bi
  • , Jaeseok Park
  • , Vibhas Deshpande
  • , Orlando Simonetti
  • , Gerhard Laub
  • , Debiao Li*
  • *Corresponding author for this work

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Coronary magnetic resonance angiography (MRA) acquired using steady-state free precession (SSFP) sequences tends to suffer from image artifacts caused by local magnetic field inhomogeneities. Flow- and gradient-switching-induced eddy currents are important sources of such phase errors, especially under off-resonant conditions. In this study, we propose to reduce these image artifacts by using a linear centric-encoding (LCE) scheme in the phase-encoding (PE) direction. Abrupt change in gradients, including magnitude and polarity between consecutive radiofrequency cycles, is minimized using the LCE scheme. Results from numeric simulations and phantom studies demonstrated that signal oscillation can be markedly reduced using LCE as compared to conventional alternating centric-encoding (ACE) scheme. The image quality of coronary arteries was improved at both 1.5 and 3.0 T using LCE compared to those acquired using ACE PE scheme (1.5 T: ACE/LCE=2.2±0.8/3.0±0.6, P=.02; 3.0 T: ACE/LCE=2.1±1.1/3.0±0.8, P=.01). In conclusion, flow- and eddy-currents-induced imaging artifacts in coronary MRA using SSFP sequence can be markedly reduced with LCE acquisition of PE lines.

    Original languageEnglish
    Pages (from-to)1138-1147
    Number of pages10
    JournalMagnetic Resonance Imaging
    Volume25
    Issue number8
    DOIs
    Publication statusPublished - 2007 Oct

    Bibliographical note

    Funding Information:
    This work was supported, in part, by National Institutes of Health grants EB002623 and HL38698 and by Siemens Medical Solutions (Chicago, IL, USA).

    Keywords

    • Coronary arteries
    • Eddy currents
    • Flow
    • High-field imaging
    • Magnetic resonance angiography (MRA)
    • SSFP

    ASJC Scopus subject areas

    • Biophysics
    • Biomedical Engineering
    • Radiology Nuclear Medicine and imaging