Abstract
In this study, four infiltration facilities (permeable pavement, infiltration gutter, infiltration trench, and infiltration well) have been investigated and compared with their flood runoff reduction effect. The SEEP/W model was used to estimate the infiltration amount of each facility, and the flood runoff reduction effect was quantified by the decrease in curve number (CN). As a result of this study, we found that: (1) the infiltration could be successfully simulated by the SEEP/W model, whose result could also be quantified effectively by the decrease in CN; (2) among the four infiltration facilities considered in this study, the infiltration well and infiltration trench were found to be most efficient and economical; (3) finally, the intervention effect of the nearby infiltration facility was found not so significant. In an extreme case where the infiltration wells were located at 1 m interval, the intervention effect was found to be just 1%.
Original language | English |
---|---|
Pages (from-to) | 118-129 |
Number of pages | 12 |
Journal | Water Science and Technology |
Volume | 74 |
Issue number | 1 |
DOIs | |
Publication status | Published - 2016 Jul |
Keywords
- Curve number (CN)
- Infiltration facility
- Runoff
- SEEP/W model
ASJC Scopus subject areas
- Environmental Engineering