Stimulation Efficiency with Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System

Hyung Min Lee, Bryan Howell, Warren M. Grill, Maysam Ghovanloo

    Research output: Contribution to journalArticlepeer-review

    17 Citations (Scopus)

    Abstract

    The purpose of this study was to test the feasibility of using a switched-capacitor discharge stimulation (SCDS) system for electrical stimulation, and, subsequently, determine the overall energy saved compared to a conventional stimulator. We have constructed a computational model by pairing an image-based volume conductor model of the cat head with cable models of corticospinal tract (CST) axons and quantified the theoretical stimulation efficiency of rectangular and decaying exponential waveforms, produced by conventional and SCDS systems, respectively. Subsequently, the model predictions were tested in vivo by activating axons in the posterior internal capsule and recording evoked electromyography (EMG) in the contralateral upper arm muscles. Compared to rectangular waveforms, decaying exponential waveforms with time constants >500 μs were predicted to require 2%-4% less stimulus energy to activate directly models of CST axons and 0.4%-2% less stimulus energy to evoke EMG activity in vivo. Using the calculated wireless input energy of the stimulation system and the measured stimulus energies required to evoke EMG activity, we predict that an SCDS implantable pulse generator (IPG) will require 40% less input energy than a conventional IPG to activate target neural elements. A wireless SCDS IPG that is more energy efficient than a conventional IPG will reduce the size of an implant, require that less wireless energy be transmitted through the skin, and extend the lifetime of the battery in the external power transmitter.

    Original languageEnglish
    Pages (from-to)1095-1106
    Number of pages12
    JournalIEEE Transactions on Biomedical Engineering
    Volume65
    Issue number5
    DOIs
    Publication statusPublished - 2018 May

    Bibliographical note

    Publisher Copyright:
    © 1964-2012 IEEE.

    Keywords

    • Implantable pulse generator
    • stimulation efficiency
    • switched-capacitor discharging stimulation
    • wireless power transmission

    ASJC Scopus subject areas

    • Biomedical Engineering

    Fingerprint

    Dive into the research topics of 'Stimulation Efficiency with Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System'. Together they form a unique fingerprint.

    Cite this