Abstract
A new space vector pulse-width modulation (SVPWM) technique to eliminate common-mode voltage (CMV) is proposed for a dual three-phase inverter fed-dual-winding fault-tolerant permanent magnet motor (FTPMM) drive. In general, since both the PWM module-1 of an inverter-1 drive and the PWM module-2 of an inverter-2 drive adopt the conventional SVPWM (CSVPWM) technique, two identical CMVs are generated in the drives. Each of the CMCs generated by the CMVs flows through the stray capacitances between the stator windings and the motor frame. These currents flow into the ground of the drive, where they are combined. Hence, in the proposed technique, each of the PWM modules adopts the remote-state PWM (RSPWM)2A and RSPWM2B. As a result, two CMVs with same absolute values and opposite polarities are generated at every switching period, and the corresponding generalized total CMV of the dual-winding FTPMM drive always becomes zero. Analytical and experimental results are provided to verify the validity of the proposed technique.
Original language | English |
---|---|
Pages (from-to) | 710-719 |
Number of pages | 10 |
Journal | Journal of Power Electronics |
Volume | 20 |
Issue number | 3 |
DOIs | |
Publication status | Published - 2020 May 1 |
Bibliographical note
Publisher Copyright:© 2020, The Korean Institute of Power Electronics.
Keywords
- Common-mode voltage (CMV)
- Dual three-phase inverter
- Dual-winding fault-tolerant permanent magnet motor (FTPMM)
- Reduced common-mode voltage PWM (RCMV-PWM)
- Remote-state PWM (RSPWM)
ASJC Scopus subject areas
- Control and Systems Engineering
- Electrical and Electronic Engineering