Abstract
The darkening of γ-irradiated glass was related to the binding of Si-O and Sn-O, and the binding of Na-O. The dosimetric range of glass color change was evaluated by colorimetry, UV-Vis spectrophotometry and ESR. Colorimetry and UV-Vis spectrophotometry, revealed linear changes up to 9 kGy. For the calibration curve of γ-irradiation, the signal of g = 2.01 observed by ESR responded most sensitively with a linear increase with up to 12 kGy.
| Original language | English |
|---|---|
| Pages (from-to) | 1365-1371 |
| Number of pages | 7 |
| Journal | Radiation Measurements |
| Volume | 43 |
| Issue number | 8 |
| DOIs | |
| Publication status | Published - 2008 Sept |
Bibliographical note
Funding Information:The financial support provided by ARPC (Agricultural R&D Center, 105092–2) and the laboratory facility for gamma irradiation provided by Greenpia Technology are gratefully acknowledged.
Keywords
- Color
- Dosimetry
- Gamma-ray
- Glass
ASJC Scopus subject areas
- Radiation
- Instrumentation