Time projection chamber at SPring-8

M. Niiyama, K. Imai, M. Nakamura, T. Yosoi, T. Ishikawa, M. Miyabe, K. Miwa, J. K. Ahn, D. S. Ahn, T. Nakano, H. Bhang, H. Fujimura, H. Kohri, Y. Sugaya, C. W. Wang, T. H. Chang, D. Oshuev

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

We have constructed a Time Projection Chamber(TPC) as the 4π detector for hadron photoproduction experiments at SPring-8. A feature of this TPC is to detect low momentum hyperons as close as 16 mm from the target center. We have studied basic performances of the TPC such as the resolution of dE/dx measurement and the spatial resolution with cosmic rays. The resolution of dE/dx measurement is 16% for minimum ionizing particles. The spatial resolution in pad plane is 280 μm and that along drift direction is 620 μm. The spatial resolution at the distance of 16 mm from the target is obtained to be 400 μm and 880 μm in pad plane and along drift direction respectively.

Original languageEnglish
Pages (from-to)C1095-C1098
JournalNuclear Physics A
Volume721
DOIs
Publication statusPublished - 2003 Jun 30
Externally publishedYes

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

Fingerprint

Dive into the research topics of 'Time projection chamber at SPring-8'. Together they form a unique fingerprint.